| No. |
Inspection field (product, product design, service, process, plant)
|
Inspection type
|
Methods and procedures, normative documents
|
Notes
|
| 1. | Non - automatic weghing instruments | - periodic inspectiom - inspection after repair |
Rules on metrological requirements on non - automatic weighing instruments ( Official Gazette on the RS No. 97/03) | Scale capacity with accuracy classes (I) up to 35 kg (II) up to 550 kg (III) and (IIII) up to 100 t Inspection of instruments with n> 3000 and without built-in internal adjustment function only on site. |
| 2. | Automatic catchweighing instruments | -subsequent inspection (periodic) -inspection after repair |
Rules on measuring instruments (Official Gazette of the RS, No. 42/06, Annex I, MI - 006) | Inspection is performed on site |
| - initial inspection - subsequent inspection (periodic) - inspection after repair |
Rules on metrological requirements on automatic weighing instruments (Official Gazette of the RS, No. 26/02) in conjunction with the 39th, 40th and 41 Article of the measuring instruments directive of the RS, No.42/06) |
| 3. | Automatic gravimetric filling weighing instuments | - subsequent inspection (periodic) - inspection after repair |
Measuring Instruments directive ( Official Gazette of the RS, No. 42/06, Annex I, MI-006) | Inspection is performed only on site. Capacity of instruments up to 2t. |
| - initial inspection - subsequent inspection (periodic) - inspection after repair |
National regulation for automatic weighing instruments(Officia Gazette of the SFRY, No. 1/84) in conjunction with the 33rd and 35th Article of National regulation for automatic weighing instruments (Official Gazette of the RS, No. 26/02) in conjunction with the 39th, 40th and 41st Article of the Measuring instruments directive (Official Gazette of the RS, No. 42/06) |
| 4. | Weighing instruments for construction purpose | -subsequent inspection (periodic) -inspection after repair |
National regulation for discontinuous totalizing automatic weighing instruments (Official Gazette of the SFRY, No. 19/86) in conjunction with the 35th Article of National regulation for automatic weighing instruments (Official Gazette of the RS, No. 26/02) in conjunction with the 40th and 41st Article of the Measuring instruments directive (Official Gazette of the RS, No. 42/06) and internal procedure ML10N18 - issue 5 |
Inspection si performed only on site. Capacity of instruments up to 10 t. |
| 5. | Weights | - initial inspection - subsequent inspection (periodic) - inspection after repair |
Rules on metrological requirements on weights with nominal masses of 1 mg to 50 kg (Official Gazette of RS, No. 20/02) Rules on metrological requirements on weights with nominal masses of 50 kg to 5000 kg (Official Gazette of RS, No. 20/02) |
ln laboratory: weights of nominal masses and accuracy classes: M2: 100 mg to 20 kg M1: 1 mg to 20 kg F2: 1 mg to 20 kg F1: 1 mg to 20 kg E2: 1 mg to 500 g On site: weights ofnominal masses and accuracy classes: M2: 100 mg to 20 kg M1: 100 mg to 20 kg n=5000: 500 kg |
| 6. | Exhaust gas analysers (spark ignition) | -initia/ inspection -subsequent inspection (periodic) -extraordinary inspection |
- initia/ inspection - subsequent inspection (periodic) - extraordinary inspection Rules on metrogical requirements on exhaust gas analysers (spark ignition) (Official Gazette of the RS, No. 5/98, 83106) |
Inspection is performed only on site. |
| 7. | Exhaust gas analysers (compression ignition) | - initial inspection - subsequent inspection (periodic) - extraordinary inspection |
Rules on metrological requirements on exhaust gas analysers (compression ignition) (Official Gazette of RS, No. 106/01) | Inspection is performed only on site. |
| 8. | Sphygmo - manometers | -subsequent inspection (periodic) - extraordinary inspection |
National regulation for initial verification of blood pressure measuring devices (Official Gazette of the RS, No.24/04, 37/06) | |
| 9. | Tire pressure measuring instruments | - initial inspection - subsequent inspection (periodic) -extraordinary inspection |
Rules on metrological requirements on tire pressure measuring, (Official Gazette of RS, No. 15/02, 76/03) Rules on metrological requirements on tire pressure measuring, with EEC marks and symbols (Official Gazette of RS, No. 74/01) |
|
| 10. | Roller brake testers | - initial inspection - subsequent inspection (periodic) -extraordinary inspection |
Rules on metrological requirements on roller brake testers (Official Gazette of RS, No. 51/07) | Inspection is performed only on site. |
| 11. | Length measures for general purpose | - initial inspection - subsequent inspection (periodic) - extraordinary inspection |
Rules on metrological requirements length measures for general purpose (Official Gazette of RS, No. 76/01) in conjunction with the 39th, 40th and 41st Article of Measuring instruments directive (Official Gazette of RS, No. 42/06) | Inspection only in the premises of the inspection body. |
| 12. | Material measures of length | - subsequent inspection (periodic) - extraordinary inspection |
Measuring instruments directive (Official Gazette of RS, No. 42/06, Annex I, MI-008) | Inspection only in the premises of the inspection body. |
| 13. | Length measuring instruments | -initial inspection -subsequent inspection (periodic) -extraordinary inspection |
National regulation for length measuring instruments (Official Gazette of RS, No. 37/02, 79/05) in conjunction with the 39th, 40th and 41st Article of the Measuring instruments directive (Official Gazette of RS, No. 42/06 | |
| -subsequent inspection (periodic) -extraordinary inspection |
Measuring instruments directive (Official Gazette of RS, No. 42/06, Annex 1, Chapter M1-009 |
| 14. | Inspection of steam sterilizers, autoclaves | -initial inspection -subsequent inspection (periodic) -extraordinary inspection |
SIST EN 285:2006 Srerilization-Steam sterilizers - Large sterilizers SIST EN ISO 17665-1:2006 Sterilization of health care |
Inspection in the premises of the inspection body and on site. |
| 15. | Fired or otherwise heated pressure equipment with risk of overheating: -steam generators - steam sterilizers* -autoclaves* * directly heated sterilizers or autoclaves |
-inspection before use (initial inspection) -subsequent inspection (periodic) during use (external examination, internal examination, pressure test) -extraordinary inspection | Rules on examination and testing ofpressure equipment (Official Gazette of the RS, No. 92/08, Article 17) | Inspection of fired equipment for Groups 1 and 2 of Annex I of the National regulation. Inspection only on place of instrument use. |
| 16. | Pressure vessels: -simple pressure vessels -for air and nitrogen - for hot water and steam - heat exchangers -steam sterilizers* -autoclaves* * indirectly heated sterilizer or autoclave |
-inspection before use (initial inspection) -subsequent inspection (periodic) during use (external examination, internal examination, pressure test) -extraordinary inspection |
Rules on examination and testing ofpressure equipment (Official Gazette of the RS, No. 92/08, Article 17) | Inspection of pressure vessels for Groups 4 and 5 of Annex I of the National regulation. Inspection only on place of instrument use. |
| 17. | Pipelines -for hot water and steam -for heating systems with water -for compressed air |
-inspection before use (initial inspection) -subsequentinspection (periodic) during use (extemal examination, pressure test) -extraordinary inspection |
Rules on examination and testing of pressure equipment (Official Gazette of the RS, No. 92/08, Article 17) | Inspection ofpipelines for Group 9 of Annex I of the National regulation. Inspection only on place of instrument use. |
| 18. | Protection equipment: -safety valves |
-inspection of adjustment and functionality | Intemal procedure ML10N80, issue 3 | Inspection is petformed for safety valves which form part of pressure equipment specified in items 15th, 16th and 17th of this table. Inspection only on place of instrument use. |
| 19. | Min weight of non-automatic weighing instruments | Intemal procedure ML10N93, issue 2 |